The tariff classification of Silicon Biosystems’s DEPArray System and the DEPArray A300K Disposable Cartridge from Italy

Save the HS code this ruling classifies to a free watchlist (5 codes, no card) and keep the figures you look up in one place.A free account covers this page; Pro adds 100-code watchlists and rate-change alerts.

Create a free account

Active· CBP ruling HQ N169075· Issued

Ruling
HQ N169075
Issued
Category
Classification
HS prefixes
9027.50 · 9027.90
Tariff numbers
9027.50.4015, 9027.90.5450

ProKeep the code this ruling classifies on a watchlist. Free tracks 5 HTS codes; Pro tracks up to 100 and alerts you when a rate moves.Watchlist: free 5 codes, Pro 100 + rate alerts.

Track in Pro — $49/mo

Frequently asked questions

What did CBP ruling HQ N169075 decide?

We believe neither subheading 8543.30.00, HTSUS, nor subheading 9027.20.50, HTSUS, applies to your apparatus.

The applicable subheading for the DEPArray System will be 9027.50.4015, Harmonized Tariff Schedule of the United States (HTSUS), which provides for instruments and apparatus for physical or chemical analysis: other instruments and apparatus using optical radiations (ultraviolet, visible or infrared): electrical, chemical analysis instruments and apparatus. The rate of duty will be free.

The applicable subheading for the DEPArray A300K disposable microfluidic cartridge will be 9027.90.5450, Harmonized Tariff Schedule of the United States (HTSUS), which provides for parts and accessories of electrical instruments and apparatus: other: of instruments and apparatus of subheading 9027.20, 9027.30, 9027.50 or 9027.80, other: of articles of subheading 9027.50.40. The rate of duty will be free. Source: US Customs and Border Protection ruling HQ N169075 (issued 2011-06-27), https://rulings.cbp.gov/ruling/N169075.

Which tariff numbers and HS headings does HQ N169075 cover?

Its subject line reads “The tariff classification of Silicon Biosystems’s DEPArray System and the DEPArray A300K Disposable Cartridge”. HQ N169075 cites 2 tariff numbers (9027.50.4015 and 9027.90.5450) and 2 HS headings (9027.50 and 9027.90), issued 2011-06-27. Other rulings on 9027.50 are grouped at /rulings/family/9027-50.html.

Is CBP ruling HQ N169075 still in effect?

Status at last retrieval (2026-10-29): Active. Issued 2011-06-27 — 15 years and 4 months before that snapshot; the CROSS mirror at 2026-10-29 lists no revocation.

Where can I read the full text of ruling HQ N169075?

HQ N169075 is reprinted above in full — 5,982 characters, 26 paragraphs. The filing itself sits at https://rulings.cbp.gov/ruling/N169075.

Ruling text

N169075

June 28, 2011

CLA-2-90:OT:RR:NC:N4:414 

CATEGORY:	Classification

TARIFF NOS.: 9027.50.4015; 9027.90.5450 

Mr. Craig A. Lewis
Hogan Lovells US LLP
Columbia Square
555 Thirteenth Street, NW
Washington, DC 20004

RE:	The tariff classification of Silicon Biosystems’s DEPArray System and the DEPArray A300K Disposable Cartridge from Italy

Dear Mr. Lewis:

In your letter dated May 27, 2001 you requested a tariff classification ruling on behalf of Silicon Biosystems, Inc.  You have requested a ruling on the Silicon Biosystems DEPArray System (the DEPArray), and on the disposable cartridge that is used in the DEPArray, when imported separately from the DEPArray.

The DEPArray is an instrument for analysis of cells and interactions between cells.  The core technology is based on dielectrophoresis principles, namely, the ability of a non-uniform electric field to exert different forces on neutral but polarisable particles in a liquid medium.  As a result of dielectrophoresis forces, particles in the liquid medium migrate at different speeds and to different locations.  

The DEPArray consists of an instrument with electronics, fluorescence microscopy, a CCD (charged coupled device) camera, and software that works in conjunction with a single-use disposable microfluidic (MF) cartridge.  The software-controlled dielectrophoresis instrument and programmable electrodes in the cartridge create a non-uniform electric field.  The frequency and the polarity pattern of the electric field may be adjusted based on the analytical needs.  The electric field can suspend and segregate cells with great selectivity, up to the level of individual cells.  

Cells in the MF cartridge, which have been treated with fluorescent dyes, are scanned by the fluorescence microscope with the image data captured by the CCD camera.  Cell selection and analysis can be performed based on the presence or absence of specific fluorescence signals, the intensity of the signals, and cell morphology.  Users can also use the software to compare and visualize individual cells side by side and use scatter plots or histograms based on the fluorescent measurements to identify populations of cells of interest.  A secondary function of the instrument is the separation and collection of specific cells from the MF cartridge for further molecular analysis with other equipment.    

The DEPArray A300K is the disposable MF cartridge used in the DEPArray.  The operator loads the recovery buffer and the sample for analysis onto the MF cartridge and inserts it into the DEPArray for analysis.  The DEPArray cannot function without the MF cartridge, and it has no other use than in this system.  The MF cartridges are used only once.  They will be imported with the complete DEPArray and imported separately as replacement cartridges.

You propose classification in subheading 9027.20.50, Harmonized Tariff Schedule of the United States (HTSUS) for the DEPArray System dielectrophoresis apparatus.  Machines and apparatus for electrophoresis are, inter alia, eo nomine in 8543.30.00, HTSUS, and electrophoresis instruments are, inter alia, eo nomine in 9027.20.50, HTSUS.  

However, dielectrophoresis is quite different from electrophoresis, as dielectrics (insulators) are different from other electrical items.  While both dielectrophoresis and electrophoresis can be considered as electroseparation processes, the differences are major.  For example, per www.separationsnow.com/coi/cda/detail.cda?id=12505&type=Feature&chId=2&page=1
“Although electrophoresis is a highly popular separation method, it can only separate charged particles. Dielectrophoresis (DEP), on the other hand, doesn't suffer from this limitation… The force generated by the DEP effect depends partially on the size of the particle, with large particles subject to greater forces than smaller ones.”

Electrophoresis is, per, e.g., wordnetweb.princeton.edu/perl/webwn, “the motion of charged particles in a colloid under the influence of an electric field; particles with a positive charge go to the cathode and negative to the anode.”

We distinguish the rulings you cite regarding electrophoresis instruments on that basis.

We note that, although the March 5, 2011 letter to your office from Silicon Biosystems proposes classification is heading 9027, HTSUS, it does not propose specifically classification in 9027.20.50, HTSUS. 

We believe neither subheading 8543.30.00, HTSUS, nor subheading 9027.20.50, HTSUS, applies to your apparatus. 

The applicable subheading for the DEPArray System will be 9027.50.4015, Harmonized Tariff Schedule of the United States (HTSUS), which provides for instruments and apparatus for physical or chemical analysis: other instruments and apparatus using optical radiations (ultraviolet, visible or infrared): electrical, chemical analysis instruments and apparatus.  The rate of duty will be free.

The applicable subheading for the DEPArray A300K  disposable microfluidic cartridge will be 9027.90.5450, Harmonized Tariff Schedule of the United States (HTSUS), which provides for parts and accessories of electrical instruments and apparatus: other: of instruments and apparatus of subheading 9027.20, 9027.30, 9027.50 or 9027.80, other: of articles of subheading 9027.50.40.  The rate of duty will be free.

Duty rates are provided for your convenience and are subject to change.  The text of the most recent HTSUS and the accompanying duty rates are provided on World Wide Web at http://www.usitc.gov/tata/hts/.

This ruling is being issued under the provisions of Part 177 of the Customs Regulations (19 C.F.R. 177).

A copy of the ruling or the control number indicated above should be provided with the entry documents filed at the time this merchandise is imported.  If you have any questions regarding the ruling, contact National Import Specialist Barbara Kiefer at (646) 733-3019.

Sincerely,




Robert B. Swierupski
Director
National Commodity Specialist Division