What did CBP ruling HQ 087597 decide?

The instant air and precipitation sampling equipment is properly classifiable under 8479.89.90, HTSUSA, which provides for: "[m]achines and mechanical appliances having individual functions, not specified or included elsewhere in this chapter: [o]ther...: [o]ther: [o]ther." The rate of duty is 2.2% ad valorem, if the requirements of the United States-Canada Free Trade Agreement are met. Source: US Customs and Border Protection ruling HQ 087597 (issued 1990-11-27), https://rulings.cbp.gov/ruling/087597.

Which tariff numbers and HS headings does HQ 087597 cover?

Its subject line reads “Sampling Equipment; Precipitation Samplers; Air Samplers; Data Logger; Parts; Accessories; Machines and”. HQ 087597 cites 1 tariff number (8479.89.90) and 1 HS heading (8479.89), issued 1990-11-27. Other rulings on 8479.89 are grouped at /rulings/family/8479-89.html.

Is CBP ruling HQ 087597 still in effect?

Status at last retrieval (2026-10-29): Active. Issued 1990-11-27 — 35 years and 11 months before that snapshot; the CROSS mirror at 2026-10-29 lists no revocation.

Where can I read the full text of ruling HQ 087597?

HQ 087597 is reprinted above in full — 6,868 characters, 42 paragraphs. The filing itself sits at https://rulings.cbp.gov/ruling/087597.

Ruling text

HQ 087597

                        November 27, 1990

CLA-2 CO:R:C:G  087597 MBR

CATEGORY:  Classification

TARIFF NO.:  8479.89.90

Mr. Wim Smits
Air Quality Technician
Ontario Ministry of the Environment
421 James St. South
Thunder Bay, Ontario, Canada
P7E 2V6

RE:  Sampling Equipment; Precipitation Samplers; Air Samplers;
     Data Logger; Parts; Accessories; Machines and Mechanical
     Appliances, not Specified or Included Elsewhere

Dear Mr. Smits:

     This is in reply to your letter of July 9, 1990, requesting
classification of air and precipitation sampling equipment and a
data logger, under the Harmonized Tariff Schedule of the United
States Annotated (HTSUSA).

FACTS:

     The items to be imported are: (1) M.I.C type A precipitation
sampler (to determine metals in precipitation), (2) M.I.C. type B
precipitation sampler (to determine organics in precipitation),
(3) Hi Vol air sampler (to determine toxics in air), (4) Low Vol
air sampler (to determine metals in air), and (5) data logger
(for electronic logging of relevant data).  Items 1-4 are
manufactured in Canada, whereas, item 5, the data logger, is a
product of the United States.  The Ontario Ministry of the
Environment plans to use these machines in a program to monitor
the toxics in precipitation and air in the Great Lakes Basin.  A
monitoring site will be established on each of the Great Lakes.

ISSUE:

     What is the classification of air and precipitation sampling
equipment, under the Harmonized Tariff Schedule of the United
States Annotated (HTSUSA)?  Since the data logger is a product of
the United States, we will not issue a classification decision on
this apparatus.

                               -2-

LAW AND ANALYSIS:

     The General Rules of Interpretation (GRI's) to the HTSUSA
govern the classification of goods in the tariff schedule.  GRI 1
states, in pertinent part:

     ...classification shall be determined according to the terms
     of the headings and any relative section or chapter notes...

     The air and precipitation sampling equipment is prima facie
classifiable under the following headings:

9027 Instruments and apparatus for physical or chemical
     analysis...:

9027.80.40 Other instruments and apparatus: Electrical

*    *    *    *    *    *    *    *    *    *    *    *    *

9027 Instruments and apparatus for physical or chemical
     analysis...:

9027.90.40 Parts and accessories

*    *    *    *    *    *    *    *    *    *    *    *    *

8479 Machines and mechanical appliances having individual
     functions, not specified or included elsewhere in this
     chapter: [o]ther...: [o]ther: [o]ther:

8479.89.90 Other machines and mechanical appliances: Other

     Heading 9027, HTSUSA, provides for: "[i]nstruments and
apparatus for physical or chemical analysis...."  Clearly, the
precipitation samplers and air samplers are not instruments and
apparatus for physical or chemical analysis since their specific
design and function is to acquire samples, rather than the
performance of physical or chemical analysis.  Further, you have
submitted information emphatically stating that these devices do
not perform physical or chemical analysis.

     The Harmonized Commodity Description and Coding System
Explanatory Notes (EN) to heading 9027, HTSUSA, page 1518,
state:

     This heading excludes machines or apparatus (whether or not
     electric) of the type classified in Section XVI, whether or
     not, in view of their low output, small size and general
     structure, they are obviously intended for use in
     laboratories (e.g., for preparing or treating specimens).
     The heading therefore excludes ovens, autoclaves, drying or
     steaming ovens or cabinets; desiccators; crushers and
                               -3-

     mixers; centerfuges; stills, presses; filters and filter
     presses; stirrers; etc."

     Webster's New World Dictionary, Third College Edition,
(1988), defines "prepare" as follows:

     ...to set in order, get ready, to bring forth, bear; to
     make ready, usually for a specific purpose; make suitable;
     fit; adapt; train...

     Clearly, the function of the air and precipitation samplers
is "to set in order," "get ready," "bring forth" and "bear"
samples for physical or chemical analysis.  Thus, the samplers
"prepare" samples, and in so doing, are thereby excluded from
heading 9027, HTSUSA, in accordance with the direction of the EN
governing heading 9027, HTSUSA.

     The Explanatory Notes, although not dispositive, should be
looked to for the proper interpretation of the HTSUSA.  See 54
Fed. Reg. 35128 (August 23, 1989).

     Additionally, the air and precipitation samplers are not
classifiable as "parts" because they are not an integral,
constituent and component part necessary to the proper
functioning of any instrument or apparatus for physical or
chemical analysis.  Furthermore, the samplers are not
classifiable as "accessories" because they do not add to the
effectiveness of any instrument or apparatus for physical or
chemical analysis.  See United States v. Liebert, 450 F.2d 1405
(1971).

HOLDING:

     The instant air and precipitation sampling equipment is
properly classifiable under 8479.89.90, HTSUSA, which provides
for: "[m]achines and mechanical appliances having individual
functions, not specified or included elsewhere in this chapter:
[o]ther...: [o]ther: [o]ther."  The rate of duty is 2.2% ad
valorem, if the requirements of the United States-Canada Free
Trade Agreement are met.

EFFECT ON OTHER RULINGS:

     HQ 084210, dated July 12, 1989, held that the Biotest RCS
Centrifugal Air Sampler was classifiable under 9027.10.60,
HTSUSA, which provides for: "[i]nstruments and apparatus for
physical or chemical analysis (for example...gas or smoke
analysis apparatus)...[g]as or smoke analysis apparatus: [o]ther:
[o]ther."  This ruling held that "the air sample permits air
quality analysis."  It is now Customs position that collecting
air samples, which subsequently "permits" air quality analysis to
be performed, (but does not perform any analysis), does not
                               -4-

qualify air sample acquisition equipment for classification under
9027, HTSUSA, which provides for: "[i]nstruments and apparatus
for physical or chemical analysis."  Therefore, the Biotest RCS
Centrifugal Air Sampler is properly classifiable under
8479.89.90, HTSUSA, which provides for: "[m]achines and
mechanical appliances having individual functions, not specified
or included elsewhere in this chapter: [o]ther...: [o]ther:
[o]ther."  Ruling Letter HQ 084210, (July 12, 1989), is revoked
under authority of section 177.9(d), Customs Regulations.

                              Sincerely,




                              John Durant, Director
                              Commercial Rulings Division